Name: SP-150
Product catalog: PFC function power supply

Print this Page        Skype Online

E-mail Us                QQ

Whatsapp               wangwang

Facebook                Youtube

Wechat
150W Single Output with PFC Function   SP-150 series
Features:
·Universal AC input/ full range
·Built-in active PFC function, PF>0.93
·100% full load burn-in test
·Protections: Short circuit/ Over load / Over voltage/ Over temperature
·Built-in constant current limiting circuit
·LED indicator for power on
·Remote ON-OFF control (Optional)
·Fixed switching frequency at PF: 67KHz  PWM: 134 KHz
·2 years warranty


SPECIFICATIONS  
OUTPUT  
Model SP-150-5 SP-150-7.5 SP-150-12 SP-150-13.5 SP-150-15 SP-150-24 SP-150-27 SP-150-48
DC Voltage 5V 7.5V 12V 13.5V 15V 24V 27V 48V
Rated Current 30A 20A 12.5A 11.2A 10A 6.3A 5.6A 3.2A
Current Range 0-30A 0-20A 0-12.5A 0-11.2A 0-10A 0-6.3A 0-5.6A 0-3.2A
Rated Power 150W 150W 150W 151.2W 150W 150W 151.2W 153.6W
Ripple & Noise 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
DC Adjustment Range -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10% -5%,+10%
Voltage Tolerance ±2% ±2% ±2% ±2% ±2% ±1% ±1% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1% ±1% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise, Hold Up Time 700ms,400ms,20ms at full load
   
INPUT  
Voltage Range 85~264 VAC   47-63Hz;120~370VDC
AC Current 2.5A/115 VAC   1.2A/230VAC
Power Factor PF>0.93/230VAC,PF>0.97/115VAC at full load
Efficiency 77.50% 81% 84% 84% 85% 85% 85% 85%
Inrush Current Cold start 45A/230VAC
Leakage Current <2mA/240VAC
   
PROTECTION  
Over Load 105%-150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 110%~135%
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. TSW1(Power transistor) When temp .in 95±5 ℃ shutdown o/p voltage temp . <95±5 ℃O/I auto-recovery.
Function  
Remote Control (option) CN1:4~10VDC POWER ON, <0~0.8VDC POWER OFF
   
ENVIRONMENT  
Working Temp. Humidity -10℃~+55℃; 20%~90% RH non-condensing
Storage Temp. Humidity -20℃~+85℃; 10%~95% RH 
Temp. Coefficient ±0.05%/℃(0~50℃)
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/25℃/70% RH
   
STANDARD  
Safety Standard Design refer to UL60950-1,TUV EN60950-1
EMC Standard Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024, light industry level, criteria A 
   
OTHERS  
Dimension 199*99*50mm(L*W*H)
Weight 0.76Kg;20pcs/16.4kg/1.28CUFT
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 
3.Tolerance: includes set up tolerance, line regulation and load regulation. 
4.The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.


If you have any enquiry about quotation or cooperation , please feel free to email us at Leyu@leyuelec.com or use the following enquiry form . Our sales representative will contact you within 24 hours. Thank you for your interest in our products.