1500W Single Output with Parallel Function   SCN-1500 series
Features: 
•High reliability, low ripple
•AC input voltage AC200~260V
•Protections: Short circuit/ Over load/Over voltage/ Over temperature
•Built-in remote ON-OFF control and remote sense function
•With parallel function
•Can adjust from 40%~100% output voltage by external:control 2-5V
•Forced air cooling by built-in DC fan
•2 years warranty

SPECIFICATIONS  
OUTPUT  
Model SCN-1500-12 SCN-1500-24 SCN-1500-27 SCN-1500-48
DC Voltage  12V 24V 27V 48V
Rated Current  125A 100A 62.5A 32A
Current Range  0-125A 0-100A 0-62.5A 0-32A
Rated Power  1500W 1500W 1500W 1536W
Ripple & Noise  120mVp-p 150mVp-p 240mVp-p 480mVp-p
Voltage Adj. Range 10.8~13.2V  20~26.4V  24~30V  41~56V
Voltage Tolerance  ±5% ±5% ±5% ±5%
Inlet Stability ±1% ±1% ±1% ±0.5%
Load Stability ±1% ±1% ±1% ±0.5%
Setup, Rise, Hold Up Time 800ms, 50ms, 16ms at full load
   
INPUT  
Voltage Range  200~260 VAC  47~63 Hz;290~370VDC
AC Current 12A/230VAC
Efficiency 83% 84% 85% 87%
Inrush Current 120A/230V 
Leakage Current <3.5mA/240VAC
   
PROTECTION  
Over Load  110%~135% Type: plusing hiccup shutdown Reset:auto recovery 
Over Temp. RTH>=80 output shutdown 
   
ENVIRONMENT  
Working Temp., Humidity -10℃~+60℃(Refer to output derating curve),20%~90%RH
Storage Temp., Humidity -20℃~+85℃, 10%~95%RH
Temp. Coefficient ±0.03%/℃(0~50℃)
Vibration 10~500Hz,2G 10min,/1cycle,Period for 60min,Each X.Y.X axes
   
SAFETY  
Withstand Voltage I/P-O/P: 1.5KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
   
STANDARD  
Safety Standard Design refer to UL1950,CSA22.2,IEC60950
EMC Standard Design refer to FCC Part 15 Class A
   
OTHERS  
Dimension 280*178*125mm(L*W*H) 
Weight 4.42Kg
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.