55W Dual Output with Battery Charger (UPS Function) ADD-55 series
Features:
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45 KHz
2 years warranty

SPECIFICATION  
MODEL  ADD-55A ADD-55B
OUTPUT    
Output number CH1 CH2 CH3 CH1 CH2 CH3
DC voltage 13.8V 5V 13.4V 27.6V 5V 26.5V
Rated Current 2.5A 3A 0.23A 1.3A 3A 0.16A
Current Range 0~3.5A 0~4A -------- 0~2A 0~4A --------
Rated Power 52.58W 55.12W
Ripple & Noise 100mVp-p 100mVp-p -------- 150mVp-p 150mVp-p --------
Voltage Adj. Range CH1:12~14.5V CH1:24~29V
Voltage Tolerance ±1.0% ±3.0% -------- ±1.0% ±3.0% --------
Line Regulation ±1.0% ±0.5% -------- ±1.0% ±0.5% --------
Load Regulation ±1.0% ±0.5% -------- ±1.0% ±0.5% --------
Setup, Rise Time 800ms,50ms/230VAC   1600ms,50ms/115VAC at full load 
Hold Up Time  80ms/230VAC    16ms/115VAC at full load
   
INPUT  
Voltage Range 88~264VAC   47~63Hz; 124~370VDC
AC Current 1.6A/115VAC   1A/230VAC
Efficiency 71% 74%
Inrush Current Cold start 20A/115VAC   40A/230VAC 
Leakage Current <1mA /240VAC
   
PROTECTION  
Over Load 105~150% rated output power
Protection type: AC Charging Mode: Hiccup mode, recovers automatically after fault condition is removed UPS Mode: Protected by internal fuse
Over Voltage CH1:14.49~18.63V CH2:28.98~37.26V
Protection type: Hiccup mode, recovers automatically after fault condition is removed 
Battery Low 9.5~11V 20~22V
   
ENVIRONMENT  
Working Temp. -10~+60℃ (Refer to “Derating Curve”) 
Working Humidity 20~90%RH non-condensing
Storage Temp., Humidity -20~+85℃,10~95%RH
Temp. Coefficient ±0.03%/ ℃(0~50℃ )on CH1 output
Vibration 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes 
   
SAFETY &EMC  
Safety Standards Design refer to UL60950-1, TUV EN60950-1 
Withstand Voltage I/P-O/P:3KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC 
Isolation Resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH 
EMC Emission Compliance to EN55022(CISPR22) Class B, EN61000-3-2,-3 
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024,light industry level, criteria A 
   
OTHERS  
Dimension 159*97*38mm(L*W*H)
Weight 0.57Kg
Packing 24pcs/13.7Kg/0.75CUFT
   
NOTE  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.