MS-15
Name: MS-15
Product catalog: Ultrathin power supply

Print this Page        Skype Online

E-mail Us                QQ

Facebook               wangwang

Linkedin
15W Single Output Switching Power Supply   MS-15 series
Low price and high reliability
105℃ output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With Short-circuit and overload protection
Compact size, light weight
100% full-load burning test
Installed with EMI filter, minimum wave 
2 years warranty

SPECIFICATIONS  
OUTPUT  
Model MS-15-5 MS-15-12 MS-15-24
DC Voltage  5V 12V 24V
Rated Current  3A 1.3A 0.7A
Current Range  0-3A 0-1.3A 0-0.7A
Rated Power  15W 15.6W 16.8W
Ripple & Noise  80mVp-p 120mVp-p 150mVp-p
Voltage Adj. Range -9%~+10% ±10% ±10%
Voltage Tolerance  ±2% ±1% ±1%
Inlet Stability ±0.5% ±0.5% ±0.5%
Load Stability ±1% ±0.5% ±0.5%
Setup, Rise, Hold Up Time  200s,100ms,30ms at full load
   
INPUT  
Voltage Range  100~240VAC   47-63Hz; 240~370VDC
AC Current 0.5A/115V   0.25A/230V
Efficiency 76% 78% 80%
Inrush Current  Cold-start current 15A/115V   30A/230V 
Leakage Current <0.5mA/240VAC
   
PROTECTION  
Over Load 105%~150% rated output power
Protection type: Fold back current limiting Reset: auto recovery
Over Voltage …………
Over Temp. …………
   
ENVIRONMENT  
Working Temp., Humidity -10℃~+60℃(Refer to output derating curve), 20%~90%RH
Storage Temp., Humidity -20℃~+85℃,10%~95% RH non-condensing
Temp. Coefficient ±0.02%/℃(0~50%)
Vibration 10~500Hz,2G 10min,/1cycle,Period for 60min,each axes 
   
SAFETY  
Withstand Voltage I/P-O/P: 1.5KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
   
STANDARD  
Safety Standard Meet UL1012 requirement
EMC Standard Meet EN55022, class A
   
OTHERS  
Dimension 84*58*38mm(L*W*H)
Weight 0.2Kg
   
NOTE  
1.The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70% RH.Humidity.
2.Error.include the setting error,line stability and load stability.
3.Wave test:adopting “A12”double wire for 20MHz,and 0.1UF & 47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.